Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Rev. bras. cardiol. invasiva ; 23(3): 166-172, jul.-set.2015. tab, ilus, graf
Article in Portuguese | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-794192

ABSTRACT

Introdução: Estudos recentes têm demonstrado a eficácia do implante transcateter valve-in-valve para otratamento de disfunção de biopróteses em pacientes de alto risco cirúrgico. Apresentamos nossa experiênciainicial com o implante valve-in-valve.Métodos: Caracterizamos o perfil clínico, ecocardiográfico e do procedimento, e reportamos os resultados de médio prazo de pacientes com disfunção de bioprótese submetidos a implante valve-in-valve em posição aórtica. Resultados: Incluímos sete pacientes do sexo masculino, com idade de 72,6 ± 10,0 anos. O escore STS foi 9,6± 10,5%, e o EuroSCORE logístico foi 22,7 ± 14,7%. Três pacientes apresentavam dupla disfunção; dois tinham insuficiência; e dois exibiam estenose isolada. A via transfemoral foi utilizada em seis casos, e a transapical, em um caso. Os dispositivos implantados incluíram as próteses Sapien XT (n = 5) e CoreValve (n = 2). O sucesso do procedimento foi obtido em seis (85,7%) casos. Após o procedimento, o gradiente médio reduziu-se de 38,2 ± 9,6mmHg para 20,9 ± 5,9 mmHg, e a área valvar elevou-se de 1,2 ± 0,4 cm2 para 1,5 ± 0,5 cm2. Ao final de 1 ano, nãoocorreram óbitos e nem outros desfechos adversos significativos; 80% dos pacientes encontravam-se em classefuncional NYHA I/II. Os gradientes transvalvares e a área valvar permaneceram inalterados nesse período. Conclusões: O procedimento valve-in-valve foi eficaz na maioria dos pacientes de alto risco cirúrgico comdisfunção de bioprótese. Quando realizado em pacientes bem selecionados, resulta em desfechos clínicos e hemodinâmicos satisfatórios.


Background: Recent studies have demonstrated the efficacy of the transcatheter valve-in-valveimplantation for the treatment of bioprosthesis dysfunction in high-risk surgical patients. This study presents the initial experience with valve-in-valve implantation. Methods: Clinical, echocardiographic, and procedural profiles were characterized, and the mid-term results of patients with surgical bioprosthesis dysfunction submitted to valve-in-valve implantation in theaortic position were reported.Results: Seven male patients were included, aged 72.6 ± 10.0 years. The STS score was 9,6 ± 10,5%, andthe logistic EuroSCORE was 22.7 ± 14.7%. Three patients had combined aortic bioprosthesis failure; two had isolated regurgitation; and two had isolated stenosis. The transfemoral access was used in six cases, and the transapical access in one case. Implanted devices included Sapien XT (n = 5) and CoreValve (n = 2) prostheses. Procedural success was achieved in six (85.7%) cases. After the procedure, the mean gradient decreased from 38.2 ± 9.6 mmHg to 20.9 ± 5.9 mmHg, and the valve area increased from 1.2 ±0.4 cm2 to 1.5 ± 0.5 cm2. After 1 year, there were no deaths and no other significant adverse outcomes; 80% of patients were in NYHA functional class I/II. The transvalvular gradients and valve area remained unchanged in this period.


Subject(s)
Humans , Male , Aged , Bioprosthesis , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/therapy , Transcatheter Aortic Valve Replacement/methods , Data Interpretation, Statistical , Echocardiography/methods , Risk Factors , Prostheses and Implants/methods , Risk Assessment/methods , Drug Therapy/methods , Aortic Valve/surgery , Heart Ventricles
SELECTION OF CITATIONS
SEARCH DETAIL